Digilock Versa Standard Cabinet Locks

This page covers Versa Standard in the legacy Numeris Versa family for cabinets, furniture and lockers. It is relevant to facilities matching existing workplace storage, drawers or locker installations. Identify the exact generation, interface and locking mechanism before comparing replacement options, and use the quote process to confirm current availability and fit.

Product Details

Interface

Keypad or RFID interface

Legacy Numeris Versa documentation covers keypad and RFID configurations. Confirm the credential interface and management method fitted to your furniture or locker. Accessibility depends on the selected interface, accessories and complete installation. Ask about the appropriate user-key or lever option for the exact model; do not assume that every configuration meets every project requirement.

Power: legacy keypad mounting differences

The legacy Versa Standard keypad data sheet dated February 21, 2019 specifies two lithium CR2450 batteries for surface-mount versions and four premium AAA batteries for recess-mount versions. Do not apply those specifications automatically to an RFID model or a newer generation. Match the exact guide and installed battery compartment; battery life depends on configuration and use.

Body Style

Finish and matching

The legacy illustrations show brushed nickel and black. For a matching order, provide the existing finish and confirm the finish offered for the quoted configuration; illustrations do not establish current availability.

Body and orientation

Record whether the existing Versa Standard installation is vertical or horizontal, together with the handle arrangement and dimensions. Do not choose a replacement using the front shape alone.

Locking Options

Manual cam locking

Cam configurations are used on compatible cabinets, drawers and lockers. Record the existing cam shape, offset, rotation and door preparation; a similar-looking front unit is not enough to establish a retrofit match.

Auto-relocking configuration

An auto-relocking spring-latch configuration is intended for assigned-use applications. Confirm the exact rear unit and operating mode before selecting it for a cabinet or locker.

Retrofit compatibility

Retrofit compatibility

Versa Standard retrofit suitability depends on the existing furniture lock, mounting opening, door thickness and rear locking mechanism. Have the original model information and front/rear photos available so the proposed configuration can be checked.

Mounting review

Use the installation guide for the exact Versa Standard generation and mounting configuration. Confirm dimensions and any model-specific plug, cam or hardware before modifying a door; one set of generic mounting steps does not apply to every installation.

Management compatibility

Management features depend on the exact legacy Numeris Versa hardware and generation. An older lock is not automatically compatible with current cloud, mobile or DigiLink systems. Tell us how the existing installation is managed so compatibility can be reviewed before a quote.

Key Management

Use the Programming and Manager credentials specified for the exact Numeris Versa generation and interface. Facilities teams should keep management access under their control and confirm credential compatibility before ordering additional locks. Features such as audit capability or external power must be checked against the matching manufacturer guide.

Versa Standard Support

Digilock lists this family in its legacy product support directory. Legacy classification does not establish that every variant is discontinued or currently available.

Use the official Versa Standard manufacturer support page and choose the correct generation, interface and management type before following installation or operating instructions. If the lock cannot be identified, contact the manufacturer or your authorized facilities lead for help.

Versa Standard questions before ordering

Is Versa Standard the same as Versa Mini?

They are separate configurations within the Versa family. Compare the actual dimensions, mounting and rear mechanism; a shared family name does not make them interchangeable.

Will Versa Standard fit an existing cabinet lock opening?

A fit check requires the mounting opening, door thickness, cam or latch arrangement and furniture-lock details. Use the matching installation guide and confirm the proposed configuration before modifying the cabinet.

Does every Versa Standard model use the same batteries?

No. Legacy documentation distinguishes battery arrangements by mounting and configuration, and newer generations can differ. Check the exact guide and existing compartment rather than using a blanket battery list.

Does the legacy Versa Standard page establish mobile-management compatibility?

No. Current cloud or mobile features should not be assumed for a legacy Numeris installation. Describe the existing management system and ask for a compatibility review as part of the quote.

For an identification or purchasing question, contact Digital Locks Online or use this page’s quote form. Do not include access codes or sensitive management credentials.

Versa Keypad

Versa RFID

Request a Quote

Request a Versa Standard quote from Digital Locks Online. Include the quantity, locker or cabinet application, existing model or generation, interface, mounting arrangement and shared- or assigned-use requirement. Have front and rear photos ready for the team if identification is needed. The quote process should confirm current availability and a suitable matching option before you order.